WMNUT − Dockable UPS Monitor
wmnut [-A T1 T2] [-b BlinkRate] [-B BeepVolume] [-C CriticalLevel] [-d display] [-h] [-l] [-L LowLevel] [-U upsname] [-v] [-V] [-w]
WMNUT is an UPS Monitor. It is used to visually display and interpret details of up to 9 UPSs status via NUT - Network UPS Tools framework.
WMNUT is dockable using WindowMaker and AfterStep window-managers; under other window-managers, WMNUT should be used with "-w" option to appear as a nicely-sized 64x64 application with a background.
WMNUT provides the following information:
− Status of power supply (Blinking Red/Yellow/Green colored
meter/battery),
− Percentage of battery remaining (numeric and meter),
− Load level percentage on output (numeric, if available),
− Runtime to empty, ie time left to battery depletion (MM:SS),
- Communication status with UPS (Blinking Red/Green "C").
−A <T1 T2>
Send messages to users terminals when Low and critical. T1 is seconds between messages when Low. T2 is seconds between messages when Critical.
−b <BlinkRate>
Blink rate for red LED. (0 for no blinking.)
−B <Volume>
Beep at Critical Level. Volume is between -100% to 100%. This function has been disabled, at least temporarily.
−C <CriticalLevel>
Define level at which red LED turns on.
−d <display>
Use alternate display.
−h |
Display help screen. |
||
−l |
Use a low-color pixmap to conserve colors on 8-bit displays. |
−L <LowLevel>
Define level at which yellow LED turns on. CriticalLevel takes precedence if LowLevel<CriticalLevel.
−U <upsname>
Define upsname ([upsname@]hostname, default is localhost). You can use up to 9 call to -U <upsname> to monitor multiple UPSs.
−v |
Print version (includes important WMNUT info). |
||
−V |
Verbose mode : display NUT available feature and base value. |
||
−w |
Windowed mode (opposite to native withdrawn mode for Window Maker). |
None are known
Arnaud Quette <arnaud DOT quette AT free DOT fr>