sourCEntral - mobile manpages

pdf

QPING

NAME

qping − check application status of Grid Engine daemons.

SYNTAX

qping [−help] [−noalias] [−ssl|−tcp] [[[−i interval] [−info] [−f]] | [[ −dump_tag tag [param]] [−dump] [−nonewline]]] host port name id

DESCRIPTION

Qping is used to validate the runtime status of a Grid Engine service daemon. The current Grid Engine implementation allows one to query the SGE_QMASTER daemon and any running SGE_EXECD daemon. The command is used to send a SIM (Status Information Message) to the destination daemon. The communication layer of the specified daemon will respond with a SIRM (Status Information Response Message) which contains status information about that daemon. It also has options allow an administrator to observe the communication protocol data flow of a Grid Engine service daemon.

OPTIONS

−f
Show full status information on each ping interval.

First output line: The first output line shows the date and time of the request.

SIRM version: Internal version number of the SIRM (Status Information Response Message)

SIRM message id: Current message id for this connection

start time: Start time of daemon. The format is as follows:

MM/DD/YYYY HH:MM:SS (seconds since 01.01.1970)

run time [s]: Run time in seconds since start time

messages in read buffer: Number of buffered messages in the communication read buffer. The messages are buffered for the application (daemon). When this number grows too large the daemon is not able to handle all messages sent to it.

messages in write buffer: Number of buffered messages in the communication write buffer. The messages are sent from the application (daemon) to the connected clients, but the communication layer wasn’t able to send the messages yet. If this number grows too large, the communication layer isn’t able to send them as fast as the application (daemon) wants the messages to be sent.

number of connected clients: This is the number of clients actually connected to this daemon, including the current qping connection.

status: The status value of the daemon. This value depends on the application which replies to the qping request. If the application does not provide any information, the status is 99999. Here are the possible status information values for the Grid Engine daemons:

qmaster:

0 There is no unusual timing situation.

1 One or more threads has reached warning timeout. This may happen when at least one thread does not increment its time stamp for an usually long time. A possible reason for this is a high workload for this thread.

2 One or more threads has reached error timeout. This may happen when at least one thread has not incremented its time stamp for longer than 10 minutes.

3 The time measurement is not initialized.

execd:

0 There is no unusual timing situation.

1 Dispatcher has reached warning timeout. This may happen when the dispatcher does not increment its time stamp for an unusually long time. A possible reason for this is a high workload.

2 Dispatcher has reached error timeout. This may happen when the dispatcher has not incremented its time stamp for longer than 10 minutes.

3 The time measurement is not initialized.

info: Status message of the daemon. This value depends on the application which replies to the qping request. If the application does not provide any information the info message is "not available". Here are the possible status information values for the Grid Engine daemons:

qmaster:

The info message contains information about the qmaster threads, followed by a thread state and time information. Each time one of the known threads passes through its main loop the time information is updated. Since the qmaster has two message threads, every message thread updates the time. This means the timeout for the message thread (MT) can only occur when no message thread is active anymore:

THREAD_NAME: THREAD_STATE (THREAD_TIME)

THREAD_NAME:

MAIN: Main thread
signaler: Signal thread
event_master: Event master thread
timer: Timer thread
worker: Worker thread
listener: Listener thread
scheduler: Scheduler thread
jvm: Java thread

The thread names above (other than MAIN) will be followed by a 3 digit number.

THREAD_STATE:

R: Running
W: Warning
E: Error

THREAD_TIME:

Time since last timestamp updating.

After the dispatcher information comes an additional information string which describes the complete application status.

execd:

The info message contains information for the execd job dispatcher:

dispatcher: STATE (TIME)

STATE:

R: Running
W: Warning
E: Error

TIME:

Time since last timestamp updating.

After the thread information comes statistics on the malloc(3) state, if available, e.g. using mallinfo(3). If Grid Engine is built with the jemalloc(3) allocator, the statistics are not printed by default because they are in a different, verbose format. See print_malloc_info in sge_conf(5).

Monitor: If available (see MONITOR_TIME In qmaster_params in sge_conf(5)), displays statistics on threads. The data for each thread are displayed in one line. The format of this line can be changed at any time. Only the master implements monitoring.

−help
Prints a list of all options.

−i interval
Set qping interval. The default interval is one second. Qping will send a SIM (Status Information Message) after each interval.

−info
Show full status information (see −f for more information) and exit. The exit value 0 indicates no error. On errors qping returns with 1.

−noalias
Ignore host_aliases file, which is located at <sge_root>/<cell>/common/host_aliases. If this option is used it is not necessary to set any Grid Engine environment variable.

−ssl
This option can be used to specify an SSL (Secure Socket Layer) configuration. qping will use the configuration to connect to services running SSL. If the Grid Engine settings file is not sourced, you have to use the −noalias option to bypass the need for the SGE_ROOT environment variable. The following environment variables are used to specify your certificates:
SSL_CA_CERT_FILE − CA certificate file
SSL_CERT_FILE − certificates file
SSL_KEY_FILE − key file
SSL_RAND_FILE − rand file

−tcp
This option is used to select TCP/IP as the protocol used to connect to other services.

−nonewline
Dump output will not have a linebreak within a message, and binary messages are not unpacked.

−dump
This option allows an administrator to observe the communication protocol data flow of a Grid Engine service daemon. The command must be started as root, and on the host where the daemon to be observed is running.

The output is written to stdout. The environment variable "SGE_QPING_OUTPUT_FORMAT" can be set to hide columns, set a default column width, or to set a hostname output format. The value of the environment variable can be set to any combination of the following specifiers separated by a space character:

"h:X" −> hide column X
"s:X" −> show column X
"w:X:Y" −> set width of column X to Y
"hn:X" −> set hostname output parameter X.
X values are "long" or "short"

Run qping −help to see which columns are available.

−dump_tag tag [param]
This option has the same meaning as −dump, but can provide more information by specifying the debug level and message types qping should print:

−dump_tag ALL debug level

This option shows all possible debug messages (APP+MSG) for the debug levels, ERROR, WARNING, INFO, DEBUG and DPRINTF. The contacted service must support this kind of debugging. This option is not currently implemented.

−dump_tag APP debug level

This option shows only application debug messages for the debug levels, ERROR, WARNING, INFO, DEBUG and DPRINTF. The contacted service must support this kind of debugging. This option is not currently implemented.

−dump_tag MSG

This option has the same behavior as the −dump option.

host
Host where daemon is running.

port
Port which daemon has bound (used sge_qmaster/sge_execd port number).

name
Name of communication endpoint ("qmaster" or "execd"). A communication endpoint is a triplet of hostname/endpoint name/endpoint id (e.g. hostA/qmaster/1 or subhost/qstat/4).

id
Id of communication endpoint ("1" for daemons)

EXAMPLES

>qping master_host 31116 qmaster
08/24/2004 16:41:15 endpoint master_host/qmaster/1 at port 31116 is up since 365761 seconds
08/24/2004 16:41:16 endpoint master_host/qmaster/1 at port 31116 is up since 365762 seconds
08/24/2004 16:41:17 endpoint master_host/qmaster/1 at port 31116 is up since 365763 seconds

> qping −info master_host 31116 qmaster 1
08/24/2004 16:42:47:
SIRM version: 0.1
SIRM message id: 1
start time: 08/20/2004 11:05:14 (1092992714)
run time [s]: 365853
messages in read buffer: 0
messages in write buffer: 0
no. of connected clients: 4
status: 0
info: ok

> qping −info execd_host 31117 execd 1
08/24/2004 16:43:45:
SIRM version: 0.1
SIRM message id: 1
start time: 08/20/2004 11:06:13 (1092992773)
run time [s]: 365852
messages in read buffer: 0
messages in write buffer: 0
no. of connected clients: 2
status: 0
info: ok

ENVIRONMENT VARIABLES

SGE_ROOT

Specifies the location of the Grid Engine standard configuration files.

SGE_CELL

If set, specifies the default Grid Engine cell.

SGE_QPING_OUTPUT_FORMAT

See −dump option above.

The following apply when CSP security is used and can override the values deduced from the bootstrap file.
SSL_CA_CERT_FILE

CA certificate file

SSL_CERT_FILE

Certificates file

SSL_KEY_FILE

Key file

SSL_RAND_FILE

Random seed file

SEE ALSO

sge_intro(1), host_aliases(5), sge_qmaster(8), sge_conf(5), sge_execd(8).

COPYRIGHT

See sge_intro(1) for a full statement of rights and permissions.

pdf