DXTOOL

NAME

dxtool − DistoX download tool

SYNOPSIS

dxtool [ -p <port> ] [ -s <start addr> ] [ -e <end addr> ] [ -v ] [ -m|-x|-d|-r ]

DESCRIPTION

This manual page documents the dxtool command.

dxtool is a utility to download measurements from the DistoX cave surveying device

OPTIONS

Details of options are included below.

−h

Print usage help

−p <port>

Bluetooth port (default: /dev/rfcomm0)

−v

Verbose operation (dump every sent/received packet)

Operation Modes:

−m

Dump all stored measurements (default mode)

−r

Wait for DistoX-initiated transmissions (new measurements)

−x

Dump memory in hex digits

−d

Dump memory in decimal

In -m/-x/-d modes use -s/-e options to specify start and end addresses

(default: 0 ~ 0x7fff):

−s <Hex-address>

Specify start address

−e <Hex-address>

Specify end address

USAGE

During dxtool operation, it is neccessary to keep the device powered on (ie. prevent the power-off timeout). For example, by pressing random keys other than the measurement key.

Before using dxtool, you need to power on the device and estabilish a SPP connection, for example using:

sudo rfcomm connect /dev/rfcomm0 10:00:e8:be:a5:18 1

EXAMPLES

Often you can just use the command in its simplest form:
dxtool

downloads all stored data from /dev/rfcomm0
dxtool -r

waits for incoming data and downloads it
dxtool -p /dev/rfcomm1 -x -s 0x300 -e 0x500

dumps raw data in hex form from address 0x300 to 0x500, connecting via device /dev/rfcomm1

pdf